MEANWell NEL-400-5 Switching Power Supply

VOLUME DISCOUNTS
Over 2500 USD5%
Over 5000 USD10%

MEANWell NEL-400-5 Switching Power Supply (5V 80A 400W)

$38.00

Description

MEANWell NEL-400-5 Switching Power Supply

Size:215×115×30mm
Power: 400W
High efficiency up to 90%
Built-in active PFC function, PF>0.95
LED indicator for power on
Forced air cooling by built in DC Fan with fan speed control function
1U low profile 30mm
High efficiency, Long life and high reliability
Protections: Short circuit / Overload / Over voltage / over temperature
1 year warranty

Product Specifications :

ModelNEL-400-5
InputVoltage Range85~ 264VAC 120~ 370VAC
FREQUENCY RANGE47 ~ 63Hz
AC CURRENT (Typ.)3.5A/115VAC 1.5A/230VAC
LEAKAGE CURRENT<2mA / 240VAC
INRUSH CURRENT (Typ.)COLD START 65A/230VAC
EFFICIENCY (Typ.)84%
OutputRATED CURRENT80A
DC VOLTAGE5V
RATED POWER400W
CURRENT RANGE0-80A
VOLTAGED ADJ. RANGE4.5~ 5.5V
RIPPLE & NOISE (max.) Note.2150mVp-p
VOLTAGE TOLERANCE Note.3±2.0%
LOAD REGULATION Note.5 ±1.5%
LINE REGULATION Note.4 ±0.5%
HOLD UP TIME20ms at full load
SETUP, RISE TIME600ms,40ms at full load
ProtectionOVER VOLTAGE5.6~ 7V
Protection type :Shut off 0/p volltage, clamping by zener diode
OVER LOADAbove 150% rated output power
Protection type :Hiccup mode, recovers automatically after fault condition is removed
SafetyWITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
SAFETY STANDARDS Note 6UL60950-1, CB(IEC60950-1),CCC GB4943, 1:2011 approved
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC STANDARDSEN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, GB9254
Environment WORKING HUMIDITY 20 ~ 90% RH non-condensing
 WORKING TEMP -20 ~ +70 (Refer to output load derating curve)
 TEMP. COEFFICIENT ± 0.03%/℃ (0 ~ 50℃)
 STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
 VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
 Others DIMENSION 215*115*30mm (L*W*H)
MTBF1608.8K hrs min. MIL-HDBK-217F (25 ) ℃
NoteI. Al parameters NOT specialy mentioned are measured at 230VAC input. rated load and 25℃ of ambient temperature.
2 Ripple & noise are measured at 20MHz Of bandwidth by usig a I2′ twisted pair-wire terminated with a 0.1UI & 470 Parallel capacitor
3. Tolerance : includes set up tolerance. line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. For the request of GEl4943.1.the power soppy is only suable for use in the altitude 2000m below and the non tropical climate condrtion.
7. The power supply is considered a component which will be instated into a final equipment The final equipment must be re-confirmed that
it still mesh EMC drectives. For guidance on how to perform the EMC tests. please refer to ‘EMI testing of component power supplies’

Additional information

Weight1 kg
Manufaturer